Download PDF catalog
self-priming liquid ring pump type CA
Applications
For clean liquids without abrasives, without suspended solids,
non-explosive, non-aggressive for the pump materials. If the liquid to be pumped has entrained air or gas or the flow in the suction pipe is not stable. For drawing water out of a well. For increasing network pressure (follow local specifications).
Operating conditions
Liquid temperature from -10 °C to +90 °C.
Ambient temperature up to 40 °C.
Negative suction pressure up to 9 m.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n = 2900 rpm).
CA: three-phase 230/400 V ± 10%.
CAM: single-phase 230 V ± 10%, with thermal protector.
Capacitor inside the terminal box. Insulation class F. Protection IP 54.
Classification scheme IE2 for three-phase motors from 0,75 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30.
EN 60335-1, EN 60335-2-41.
Special features on request
- Other voltages.
- Frequency 60 Hz (as per 60 Hz data sheet).
- Protection IP 55.
- Special mechanical seal
- Higher or lower liquid or ambient temperatures.
Components | CA | B-CA |
Pump casing Lantern bracket |
Cast iron GJL 200 EN 1561 | Bronze G-Cu Sn 10 EN 1982 |
Impeller | Brass P- Cu Zn 40 Pb 2 UNI 5705 | |
Shaft | Chrome steel 1.4104 EN 10088 (AISI 430) |
Cr-Ni-Mo steel 1.4401 EN 10088 (AISI 316) |
Mechanical seal | Carbon - Ceramic - NBR |
3phasig | 230 V | 400 V | 1phasig | 230 V | P1 | P2 | Q m³/h |
0,12 | 0,24 | 0,38 | 0,48 | 0,6 | 0,75 | 1 | 1,2 | 1,5 | 1,89 | 2,4 | |
A | A | A | kW | kW | HP | l/min | 2 | 4 | 6,3 | 8 | 10 | 12,5 | 16 | 20 | 25 | 31,5 | 40 | ||
CA 60E B-CA 60E |
1,7 | 1 | CAM 60E B-CAM 60E |
1,6 | 0,26 | 0,15 | 0,2 | H (m) |
20 | 18 | 15,5 | 13 | 10,5 | 6,5 | |||||
CA 80E B-CA 80/A |
2,8 2,3 |
1,6 1,3 |
CAM 80E B-CAM 80/A |
3,3 3,6 |
0,72 | 0,45 | 0,6 | 36 | 35 | 33,5 | 31,5 | 29 | 26 | 22 | 15 | ||||
CA 90/A B-CA 90/A |
3 | 1,7 | CAM 90/A B-CAM 90/A |
4,5 | 0,9 | 0,55 | 0,75 | 42 | 41 | 40 | 37 | 34 | 30 | 25 | 17 | ||||
CA 91/A B-CA 91/A |
3,7 | 2,2 | CAM 91/A B-CAM 91/A |
5,7 | 1,2 | 0,75 | 1 | 53 | 51 | 48 | 44 | 39 | 34 | 26,5 | 17 |
P1 Maximum power input. | B-CA = Bronze construction. | H Total head in m. |
P2 Rated motor power output. | Toleranzen nach ISO 9906, Anhang A. |
TYPE | DN1 | DN2 | mm | kg | |||||||||||||||
ISO 228 | a | f | h1 | h2 | h3 | h4 | m1 | m2 | n1 | n2 | b | s | l2 | l3 | w | g | |||
CA60 E | G ½ | G ½ | 18 | 256 | 63 | 65 | 103 | 158 | 96 | 80 | 122 | 100 | 22 | 7 | 45 | 14 | 103 | 8 | 6 |
CA 80E | G ¾ | G ¾ | 23 | 272 | 63 | 90 | 126 | 158 | 96 | 80 | 122 | 100 | 22 | 7 | 55 | 17 | 109 | 8 | 7,6 |
CA 90/A | G1 | G 1 | 28 | 318 | 71 | 112 | 142 | 182 | 106 | 90 | 134 | 112 | 22 | 7 | 63 | 21 | 128 | 10 | 10,8 |
CA 91 /A | G1 | G 1 | 28 | 318 | 71 | 112 | 142 | 182 | 106 | 90 | 134 | 112 | 22 | 7 | 63 | 21 | 128 | 10 | 11,4 |
TYPE | DN1 | DN2 | mm | kg | |||||||||||||||
ISO 228 | a | f | h1 | h2 | h3 | h4 | m1 | m2 | n1 | n2 | b | s | l2 | l3 | w | g | |||
B-CA 60E | G ½ | G ½ | 18 | 256 | 63 | 65 | 103 | 158 | 96 | 80 | 122 | 100 | 22 | 7 | 45 | 14 | 103 | 8 | 6,8 |
B-CA 80/A | G ¾ | G ¾ | 23 | 307 | 71 | 90 | 134 | 182 | 106 | 90 | 134 | 112 | 22 | 7 | 55 | 17 | 122 | 10 | 10 |
B-CA 90/A | G 1 | G 1 | 28 | 318 | 71 | 112 | 142 | 182 | 106 | 90 | 134 | 112 | 22 | 7 | 63 | 21 | 128 | 10 | 13,1 |
B-CA 91 /A | G 1 | G 1 | 28 | 318 | 71 | 112 | 142 | 182 | 106 | 90 | 134 | 112 | 22 | 7 | 63 | 21 | 128 | 10 | 13,9 |
Subject to change!
Die Firma Linn-Pumpen GmbH übernimmt keine Haftung für Folgeschäden, welche aus evtl. fehlerhaften Informationen resultieren.