AP immersion pumps with open or closed impeller

Submersible pump in block design, tank installation. Motor in dry installation and pump housing flooded by the medium to be pumped.
Impeller: open or closed

  • Delivery rate (max)

    33.9 m³/h

  • Delivery head (min/max)

    0 / 32 m

  • Power (max)

    5.5 kW

Request design
Individually adapted to the medium, application and quantity. We advise you on the optimum design.

Performance tables - AP immersion pumps with open or closed impeller

Characteristics - closed impeller
Pump typeDelivery rate (min/max)Delivery head (max/min)Motor power (kW)
AP 80B65 - 240 l/min25 - 0 m1.5 kW
AP 90A14 - 382 l/min30 - 0 m2.2 kW
AP 90B119 - 525 l/min30 - 0 m3 kW
Characteristics - closed impeller
Pump typeDelivery rate (min/max)Delivery head (max/min)Motor power (kW)
AP 100A138 - 612 l/min38 - 0 m4 kW
AP 112B73 - 914 l/min34 - 0 m5.5 kW
Characteristics - Impeller open
Pump typeDelivery rate (min/max)Delivery head (max/min)Motor power (kW)
AP 90A85 - 461 l/min26 - 0 m4 kW
AP 90B66 - 500 l/min26 - 0 m5.5 kW
Characteristics - Impeller open
Pump typeDelivery rate (min/max)Delivery head (max/min)Motor power (kW)
AP 100A156 - 565 l/min30 - 0 m4 kW
AP 112B48 - 984 l/min32 - 0 m5.5 kW

Downloads

Data sheet (incl. characteristic curves)

Execution

  • Pump type: Vertically submerged peripheral impeller submersible pump
  • Assembly: Directly in open liquid tanks (4-5 cm above tank bottom)
  • Solids tolerance: For liquids with particles max. 2-6* mm particle size (*with open impeller).
  • Media suitability:
    - Water
    - Emulsions
    - Oil-containing media with viscosity up to 20 cSt (≈ 3°Engler)

Applications

  • Machine tools (milling machines, lathes, machining centers)
  • Glass processing machines
  • Surface treatment systems
  • Filtration systems

Operating conditions

  • Medium temperature -20 °C to +90 °C.
    Ambient temperature max. 40 °C.
    Maximum permissible pump discharge pressure 6 bar.
    Max. Particle size* 2-6 mm, max. kinem. Viscosity 20 mm 2/s

Special versions (on request)

  • Deviating voltages
  • Operation at 60 Hz

Do you still have questions or need support?

Contact us and let us work together to find the best solution for your requirements.